{"_buckets": {"deposit": "e130e3a6-8586-4927-b8d2-847e966204b2"}, "_deposit": {"id": "7379", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7379"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00007379"}, "item_10_alternative_title_19": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u8a00\u8a9e\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Virtual Figure Presentation Using a Distributed Pressure Display"}]}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "674", "bibliographicPageEnd": "2976", "bibliographicPageStart": "2970", "bibliographicVolumeNumber": "68", "bibliographic_titles": [{"bibliographic_title": "\u65e5\u672c\u6a5f\u68b0\u5b66\u6703\u8ad6\u6587\u96c6 C\u7de8"}]}]}, "item_10_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "A tactile display device is effective in the virtual reality and remote control systems. In the present paper, a matrix-type tactile display device is mounted on a computer mouse so that a human subject can feel virtual textures and defects by manipulating the mouse and keeping his finger on the tactile display. In order to establish a design method for the tactile display device, the arthors developed a matrix-type experimental tactile display device having a 4\u00d76 array of stimulus pins using bimorph piezoelectric actuators. In the tactile display device, 1.2, 1.9, 2.5 mm were utilized as the distances between adjacent stimulus pins. Using this tactile display device mounted on a mouse, we performed a series of psychophysical experiments with five male subjects in their twenties. It is found that distance between adjacent stimulus pins should be equal to the human two point threshold (1\uff5e2mm) and that the present display device can display virtual figures which are more than double area of the mouse cursor.", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/9060"}]}, "item_10_publisher_32": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_10_relation_43": {"attribute_name": "\u7570\u7248\u3067\u3042\u308b", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110002378711/", "subitem_relation_type_select": "URI"}}]}, "item_10_rights_12": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}, {"subitem_rights": "\u672c\u6587\u30c7\u30fc\u30bf\u306f\u5b66\u5354\u4f1a\u306e\u8a31\u8afe\u306b\u57fa\u3065\u304dCiNii\u304b\u3089\u8907\u88fd\u3057\u305f\u3082\u306e\u3067\u3042\u308b\u3002"}]}, "item_10_select_15": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-5024", "subitem_source_identifier_type": "ISSN"}]}, "item_10_text_14": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u5927\u5ca1, \u660c\u535a"}], "nameIdentifiers": [{"nameIdentifier": "20520", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OHKA, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "20521", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u6bdb\u5229, \u884c\u5b8f"}], "nameIdentifiers": [{"nameIdentifier": "20522", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MOURI, Yukihiro"}], "nameIdentifiers": [{"nameIdentifier": "20523", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u6749\u6d66, \u5fb3\u5b8f"}], "nameIdentifiers": [{"nameIdentifier": "20524", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SUGIURA, Tokuhiro"}], "nameIdentifiers": [{"nameIdentifier": "20525", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u4e09\u77e2, \u4fdd\u6c38"}], "nameIdentifiers": [{"nameIdentifier": "20526", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MITSUYA, Yasunaga"}], "nameIdentifiers": [{"nameIdentifier": "20527", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u53e4\u8cc0, \u6d69\u55e3"}], "nameIdentifiers": [{"nameIdentifier": "20528", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KOGA, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "20529", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "JsMecEngC_68-674-2970.pdf", "filesize": [{"value": "613.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 613700.0, "url": {"label": "JsMecEngC_68-674-2970.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/7379/files/JsMecEngC_68-674-2970.pdf"}, "version_id": "ec174336-2431-444e-88b1-2472d1606876"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "Robotics and Mechatronics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Human Interface", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Biomechanics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Psycophsics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Tactile Sensing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Distributed Pressure", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Presentation System", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u5206\u5e03\u5727\u899a\u30c7\u30a3\u30b9\u30d7\u30ec\u30a4\u88c5\u7f6e\u306b\u3088\u308b\u4eee\u60f3\u5f62\u72b6\u5448\u793a", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u5206\u5e03\u5727\u899a\u30c7\u30a3\u30b9\u30d7\u30ec\u30a4\u88c5\u7f6e\u306b\u3088\u308b\u4eee\u60f3\u5f62\u72b6\u5448\u793a"}]}, "item_type_id": "10", "owner": "1", "path": ["320/321/322"], "permalink_uri": "http://hdl.handle.net/2237/9060", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2007-11-30"}, "publish_date": "2007-11-30", "publish_status": "0", "recid": "7379", "relation": {}, "relation_version_is_last": true, "title": ["\u5206\u5e03\u5727\u899a\u30c7\u30a3\u30b9\u30d7\u30ec\u30a4\u88c5\u7f6e\u306b\u3088\u308b\u4eee\u60f3\u5f62\u72b6\u5448\u793a"], "weko_shared_id": 3}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

分布圧覚ディスプレイ装置による仮想形状呈示

http://hdl.handle.net/2237/9060
0e9b9703-7d80-45fe-a4fb-216f27bda4b2
名前 / ファイル ライセンス アクション
JsMecEngC_68-674-2970.pdf JsMecEngC_68-674-2970.pdf (613.7 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-11-30
タイトル
タイトル 分布圧覚ディスプレイ装置による仮想形状呈示
その他のタイトル
その他のタイトル Virtual Figure Presentation Using a Distributed Pressure Display
著者 大岡, 昌博

× 大岡, 昌博

WEKO 20520

大岡, 昌博

Search repository
OHKA, Masahiro

× OHKA, Masahiro

WEKO 20521

OHKA, Masahiro

Search repository
毛利, 行宏

× 毛利, 行宏

WEKO 20522

毛利, 行宏

Search repository
MOURI, Yukihiro

× MOURI, Yukihiro

WEKO 20523

MOURI, Yukihiro

Search repository
杉浦, 徳宏

× 杉浦, 徳宏

WEKO 20524

杉浦, 徳宏

Search repository
SUGIURA, Tokuhiro

× SUGIURA, Tokuhiro

WEKO 20525

SUGIURA, Tokuhiro

Search repository
三矢, 保永

× 三矢, 保永

WEKO 20526

三矢, 保永

Search repository
MITSUYA, Yasunaga

× MITSUYA, Yasunaga

WEKO 20527

MITSUYA, Yasunaga

Search repository
古賀, 浩嗣

× 古賀, 浩嗣

WEKO 20528

古賀, 浩嗣

Search repository
KOGA, Hiroshi

× KOGA, Hiroshi

WEKO 20529

KOGA, Hiroshi

Search repository
権利
権利情報 日本機械学会
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである。
キーワード
主題Scheme Other
主題 Robotics and Mechatronics
キーワード
主題Scheme Other
主題 Human Interface
キーワード
主題Scheme Other
主題 Biomechanics
キーワード
主題Scheme Other
主題 Psycophsics
キーワード
主題Scheme Other
主題 Tactile Sensing
キーワード
主題Scheme Other
主題 Distributed Pressure
キーワード
主題Scheme Other
主題 Presentation System
抄録
内容記述 A tactile display device is effective in the virtual reality and remote control systems. In the present paper, a matrix-type tactile display device is mounted on a computer mouse so that a human subject can feel virtual textures and defects by manipulating the mouse and keeping his finger on the tactile display. In order to establish a design method for the tactile display device, the arthors developed a matrix-type experimental tactile display device having a 4×6 array of stimulus pins using bimorph piezoelectric actuators. In the tactile display device, 1.2, 1.9, 2.5 mm were utilized as the distances between adjacent stimulus pins. Using this tactile display device mounted on a mouse, we performed a series of psychophysical experiments with five male subjects in their twenties. It is found that distance between adjacent stimulus pins should be equal to the human two point threshold (1~2mm) and that the present display device can display virtual figures which are more than double area of the mouse cursor.
内容記述タイプ Abstract
出版者
出版者 日本機械学会
言語
言語 jpn
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
関連情報
関連タイプ isVersionOf
関連識別子
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110002378711/
ISSN
収録物識別子タイプ ISSN
収録物識別子 0387-5024
書誌情報 日本機械学會論文集 C編

巻 68, 号 674, p. 2970-2976, 発行日 2002-10
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/9060
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 12:20:23.644283
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio