ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "22b2f6d6-36f3-4e5d-aaa7-9d1737e219bb"}, "_deposit": {"id": "9890", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "9890"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00009890", "sets": ["501"]}, "author_link": ["29849", "29850", "29851", "29852"], "item_10_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Change in Exercise Tidal Flow-Volume Loops with Added Dead Space during Exercise", "subitem_alternative_title_language": "en"}]}, "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-12-20", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "376", "bibliographicPageStart": "370", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "理学療法学", "bibliographic_titleLang": "ja"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "慢性心不全患者に生じるとされる運動時1回換気フロー・ボリューム曲線(exercise tidal flow volume loop: extFVL)の右方偏位に関与する生理学的背景を検討することを目的として予備研究を行った。健常大学生8名(男性6名,女性2名)を対象に嫌気性代謝閾値における仕事量の90%と130%で各6分間運動する2段階定常負荷試験を,400mlの外的死腔の有無により2回施行し,extFVLの位相を比較した。400mlの死腔負荷によって運動時死腔換気率は有意に増加した。extFVLは吸気終末肺気量の増加を伴って拡大したものの,右方偏位は示さなかった。したがって,運動時における死腔増加のみではextFVLの右方偏位の原因とならないことが示され,今後は他の要因に関する検討が必要と思われた。", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "The purpose of this study was to investigate the physiological factor which contributed to the right shift in exercise tidal flow-volume loop (extFVL) observed in patients with chronic heart failure by Johnson BD. Eight healthy volunteers in our college underwent two-step constant  load exercise which was composed of 90 and 130% work load of anerobic threshold under the following two conditions, in randomized order: 1) control, and 2) added dead space of 400ml. We compared extFVLs between these two conditions. The ratio of ventilatory dead space to tidal  volume during exercise was significantly increased by adding dead space. As a result, extFVLs expanded with an increase in end-inspiratory lung volume, but it did not take on the right shift. This indicates that only the increase in dead space dose not contribute to the right shift in extFVL observed in patients with chronic heart failure. Future investigation will be necessary to examine other contributing factors.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/11699"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "社団法人日本理学療法士協会", "subitem_publisher_language": "ja"}]}, "item_10_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110006153530/", "subitem_relation_type_select": "URI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "社団法人日本理学療法士協会", "subitem_rights_language": "ja"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである", "subitem_rights_language": "ja"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "02893770", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岩津, 弘太郎", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "29849", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 純生", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "29850", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IWATSU, Kotaro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "29851", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YAMADA, Sumio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "29852", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "110006153530.pdf", "filesize": [{"value": "939.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 939800.0, "url": {"label": "110006153530.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/9890/files/110006153530.pdf"}, "version_id": "b0d26000-b03d-4b3f-b1ef-a8b8fe8914ea"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "運動時1回換気フロー・ボリューム曲線", "subitem_subject_scheme": "Other"}, {"subitem_subject": "右方偏位", "subitem_subject_scheme": "Other"}, {"subitem_subject": "死腔負荷", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "死腔負荷に伴う運動時1回換気フロー・ボリューム曲線の変化に関する検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "死腔負荷に伴う運動時1回換気フロー・ボリューム曲線の変化に関する検討", "subitem_title_language": "ja"}]}, "item_type_id": "10", "owner": "1", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/11699", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-05-08"}, "publish_date": "2009-05-08", "publish_status": "0", "recid": "9890", "relation": {}, "relation_version_is_last": true, "title": ["死腔負荷に伴う運動時1回換気フロー・ボリューム曲線の変化に関する検討"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100a 雑誌掲載論文
  3. 学術雑誌

死腔負荷に伴う運動時1回換気フロー・ボリューム曲線の変化に関する検討

http://hdl.handle.net/2237/11699
http://hdl.handle.net/2237/11699
09281940-5d43-45ba-aa86-262242233772
名前 / ファイル ライセンス アクション
110006153530.pdf 110006153530.pdf (939.8 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-05-08
タイトル
タイトル 死腔負荷に伴う運動時1回換気フロー・ボリューム曲線の変化に関する検討
言語 ja
その他のタイトル
その他のタイトル Change in Exercise Tidal Flow-Volume Loops with Added Dead Space during Exercise
言語 en
著者 岩津, 弘太郎

× 岩津, 弘太郎

WEKO 29849

ja 岩津, 弘太郎

Search repository
山田, 純生

× 山田, 純生

WEKO 29850

ja 山田, 純生

Search repository
IWATSU, Kotaro

× IWATSU, Kotaro

WEKO 29851

en IWATSU, Kotaro

Search repository
YAMADA, Sumio

× YAMADA, Sumio

WEKO 29852

en YAMADA, Sumio

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 ja
権利情報 社団法人日本理学療法士協会
権利
言語 ja
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
キーワード
主題Scheme Other
主題 運動時1回換気フロー・ボリューム曲線
キーワード
主題Scheme Other
主題 右方偏位
キーワード
主題Scheme Other
主題 死腔負荷
抄録
内容記述 慢性心不全患者に生じるとされる運動時1回換気フロー・ボリューム曲線(exercise tidal flow volume loop: extFVL)の右方偏位に関与する生理学的背景を検討することを目的として予備研究を行った。健常大学生8名(男性6名,女性2名)を対象に嫌気性代謝閾値における仕事量の90%と130%で各6分間運動する2段階定常負荷試験を,400mlの外的死腔の有無により2回施行し,extFVLの位相を比較した。400mlの死腔負荷によって運動時死腔換気率は有意に増加した。extFVLは吸気終末肺気量の増加を伴って拡大したものの,右方偏位は示さなかった。したがって,運動時における死腔増加のみではextFVLの右方偏位の原因とならないことが示され,今後は他の要因に関する検討が必要と思われた。
言語 ja
内容記述タイプ Abstract
抄録
内容記述 The purpose of this study was to investigate the physiological factor which contributed to the right shift in exercise tidal flow-volume loop (extFVL) observed in patients with chronic heart failure by Johnson BD. Eight healthy volunteers in our college underwent two-step constant load exercise which was composed of 90 and 130% work load of anerobic threshold under the following two conditions, in randomized order: 1) control, and 2) added dead space of 400ml. We compared extFVLs between these two conditions. The ratio of ventilatory dead space to tidal volume during exercise was significantly increased by adding dead space. As a result, extFVLs expanded with an increase in end-inspiratory lung volume, but it did not take on the right shift. This indicates that only the increase in dead space dose not contribute to the right shift in extFVL observed in patients with chronic heart failure. Future investigation will be necessary to examine other contributing factors.
言語 en
内容記述タイプ Abstract
出版者
言語 ja
出版者 社団法人日本理学療法士協会
言語
言語 jpn
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110006153530/
ISSN
収録物識別子タイプ PISSN
収録物識別子 02893770
書誌情報 ja : 理学療法学

巻 33, 号 7, p. 370-376, 発行日 2006-12-20
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/11699
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:54:09.611695
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3