WEKO3
アイテム
Durability of Steel Bridge Metallic Coating Systems based on Combined Cyclic Corrosion Tests
http://hdl.handle.net/2237/18868
http://hdl.handle.net/2237/188688946d0fd-da08-41d7-b861-ad9ebb0a257f
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-11-11 | |||||
タイトル | ||||||
タイトル | Durability of Steel Bridge Metallic Coating Systems based on Combined Cyclic Corrosion Tests | |||||
言語 | en | |||||
著者 |
Itoh, Y.
× Itoh, Y.× Shimizu, Y.× Kitane, Y. |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | metallic coating | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | accelerated exposure test | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | steel bridge | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | acid rain | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | durability | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This paper discusses durability of four types of steel bridge metallic coating systems based on combined cyclic corrosion tests. Metallic coating systems tested in this study are zinc hot dip galvanized (ZHDG) coating, zinc-aluminum alloy (ZAA) coating, zinc-aluminum pseudoalloy (ZAPA) coating, and aluminum alloy (AA) coating. The combined cyclic corrosion test followed S6 cycle conditions specified in Japanese Industrial Standard K5621. In addition to the standard S6 cycle, S6 cycle conditions with an acid rain spray period in place of a salt water spray period were also used to evaluate the effect of acid rain on durability of metallic coating systems. Steel plates with metallic coating systems were placed in a cyclic corrosion test chamber under these two different cyclic conditions for 300 days. Durability of metallic coating systems was evaluated by coating thickness loss and remaining coating area in this study, and differences in deterioration characteristics between the salt water spray and acid rain spray combined cyclic corrosion tests were investigated. The coating thickness loss was greater in the acid rain cyclic corrosion test except for ZAPA specimens, implying that ZHDG, ZAA, and AA coatings should be used with a great care when they may be exposed to acid rain. In both salt water spray and acid rain spray cyclic corrosion tests, AA specimens showed the best durability of the four metallic coatings. | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_5794 | |||||
タイプ | conference paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
書誌情報 |
en : Proceedings of the 2nd International Civil Engineering Conference on Civil Engineering and Sustainable Development, "modernizing our infrastructure", 23rd-25th September, 2008, Mombasa, Kenya (CE2008) p. 123-130, 発行日 2008 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/18868 | |||||
識別子タイプ | HDL |