Item type |
itemtype_ver1(1) |
公開日 |
2021-06-25 |
タイトル |
|
|
タイトル |
Distribution of scatter radiation by C-arm cone-beam computed tomography in angiographic suite : measurement of doses and effectiveness of protection devices |
|
言語 |
en |
著者 |
Yamaji, Mayako
Ishiguchi, Tsuneo
Koyama, Shuji
Ikeda, Shuji
Kitagawa, Akira
Hagihara, Makiyo
Itoh, Yuji
Nakamura, Masaru
Ota, Toyohiro
Suzuki, Kojiro
|
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
権利 |
|
|
言語 |
en |
|
権利情報Resource |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
|
権利情報 |
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
scatter radiation |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
radiation protection |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
cone-beam computed tomography |
内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Distribution of radiation by C-arm cone-beam computed tomography (CBCT) in the angiographic suite and effectiveness of protection devices were assessed. CBCT image of a human phantom was obtained by a rotation of 220 degrees during 8 seconds of exposure. One hundred and twelve dosimeters were placed at different positions around the beam entry site, and color maps of dose distributions were drawn for horizontal and vertical planes. The measurements showed the highest radiation dose over 600 μGy by a single CBCT image acquisition at a distance of 60 cm from the beam entry site and a height of 90 cm from the floor. The color maps demonstrated the dose distribution to be more intense at the bilateral directions of the phantom. With the use of a ceiling-mounted transparent lead-acryl screen and a table-suspended lead curtain, the doses were reduced by 45–92 % at a direction of 210 degrees and a distance of 120 cm. |
|
言語 |
en |
出版者 |
|
|
出版者 |
Nagoya University Graduate School of Medicine, School of Medicine |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
ID登録 |
|
|
ID登録 |
10.18999/nagjms.83.2.277 |
|
ID登録タイプ |
JaLC |
関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/832.html |
収録物識別子 |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
0027-7622 |
収録物識別子 |
|
|
収録物識別子タイプ |
EISSN |
|
収録物識別子 |
2186-3326 |
書誌情報 |
en : Nagoya Journal of Medical Science
巻 83,
号 2,
p. 277-286,
発行日 2021-05
|