Efficacy of comparing coil behavior and distribution using the silicone aneurysm model: difference of coil distribution in the early filling stage |
|
言語 |
en |
著者 |
Goto, Shunsaku
Izumi, Takashi
Nishihori, Masahiro
Araki, Yoshio
Yokoyama, Kinya
Uda, Kenji
Saito, Ryuta
|
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
権利 |
|
|
言語 |
en |
|
権利情報Resource |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
|
権利情報 |
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
filling coil |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
aneurysm model |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
coil distribution |
内容記述 |
|
|
内容記述 |
This study sought to establish an experimental aneurysm model of visualizing coil insertion using radiolucent nylon coils. Moreover, this study aimed to clarify the characteristics and differences of each coil and use them clinically as indices of coil selection. The coil insertion test was performed on the 10 mm spherical silicone aneurysm model filled to a nylon coil volume embolization ratio of 11.8%. Five types of coil were randomly tested six times, and the distribution of the coils was analyzed by fluoroscopy imaging. Indices of “Area (mm2),” “Feret’s diameter (mm),” and “Circularity” were calculated from the fluoroscopic images. Among the indices, only “Area” showed a significant difference between coils (p = 0.002). On multivariate analysis, “Area” of the ED Infini was larger than those of Target XL soft and Galaxy G3 (p = 0.018 and 0.026, respectively). Furthermore, the area of the 360 soft was larger than that of G3 (p = 0.049). Analysis of the correlation between these values and the coil configuration showed that “Area” was negatively correlated with the stock-wire diameter (r = −0.50; p = 0.004) and primary coil configuration (r = −0.65; p < 0.001). When inserting the coils in the early stage, although the difference between each coil is relatively difficult to obtain, knowledge on the proper use of the coils with differences in characteristics can help in selecting the coil most appropriate for the conditions. |
|
言語 |
en |
|
内容記述タイプ |
Abstract |
出版者 |
|
|
言語 |
en |
|
出版者 |
Nagoya University Graduate School of Medicine, School of Medicine |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプresource |
http://purl.org/coar/resource_type/c_6501 |
|
タイプ |
departmental bulletin paper |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
ID登録 |
|
|
ID登録 |
10.18999/nagjms.84.4.762 |
|
ID登録タイプ |
JaLC |
関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/844.html |
収録物識別子 |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
0027-7622 |
収録物識別子 |
|
|
収録物識別子タイプ |
EISSN |
|
収録物識別子 |
2186-3326 |
書誌情報 |
en : Nagoya Journal of Medical Science
巻 84,
号 4,
p. 762-771,
発行日 2022-11
|