Hemodynamic vascular biomarkers for initiation of paraclinoid internal carotid artery aneurysms using patient-specific computational fluid dynamic simulation based on magnetic resonance imaging
http://hdl.handle.net/2237/00028514
http://hdl.handle.net/2237/00028514e7c16cd4-d9f0-4f10-abbf-706b57fb7180
名前 / ファイル | ライセンス | アクション |
---|---|---|
isoda (642.0 kB)
|
|
|
Fig1 (388.0 kB)
|
|
|
Fig2 (332.3 kB)
|
|
|
Fig3 (327.8 kB)
|
|
|
Fig4 (305.7 kB)
|
|
|
Fig5A (278.6 kB)
|
|
|
Fig5B (280.1 kB)
|
|
|
Fig6 (48.4 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-08-20 | |||||
タイトル | ||||||
タイトル | Hemodynamic vascular biomarkers for initiation of paraclinoid internal carotid artery aneurysms using patient-specific computational fluid dynamic simulation based on magnetic resonance imaging | |||||
言語 | en | |||||
著者 |
Watanabe, Tomoya
× Watanabe, Tomoya× Isoda, Haruo× Takehara, Yasuo× Terada, Masaki× Naito, Takehiro× Kosugi, Takafumi× Onishi, Yuki× Tanoi, Chiharu× Izumi, Takashi |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | “This is a post-peer-review, pre-copyedit version of an article published in [Neuroradiology]. The final authenticated version is available online at: http://dx.doi.org/10.1007/s00234-018-2002-8”. | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Intracranial aneurysm | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Computational fluid dynamics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Magnetic resonance imaging | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Wall shear stress | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: We performed computational fluid dynamics (CFD) for patients with and without paraclinoid internal carotid artery (ICA) aneurysms to evaluate the distribution of vascular biomarkers at the aneurysm initiation sites of the paraclinoid ICA. Methods: This study included 35 patients who were followed up for aneurysms using 3D time of flight (TOF) magnetic resonance angiography (MRA) and 3D cine phase-contrast MR imaging. Fifteen affected ICAs were included in group A with the 15 unaffected contralateral ICAs in group B. Thirty-three out of 40 paraclinoid ICAs free of aneurysms and arteriosclerotic lesions were included in group C. We deleted the aneurysms in group A based on the 3D TOF MRA dataset. We performed CFD based on MR data set and obtained wall shear stress (WSS), its derivatives, and streamlines. We qualitatively evaluated their distributions at and near the intracranial aneurysm initiation site among three groups. We also calculated and compared the normalized highest (nh-) WSS and nh-spatial WSS gradient (SWSSG) around the paraclinoid ICA among three groups. Results: High WSS and SWSSG distribution were observed at and near the aneurysm initiation site in group A. High WSS and SWSSG were also observed at similar locations in group B and group C. However, nh-WSS and nh-SWSSG were significantly higher in group A than in group C, and nh-SWSSG was significantly higher in group A than in group B. Conclusion: Our findings indicated that nh-WSS and nh-SWSSG were good biomarkers for aneurysm initiation in the paraclinoid ICA. | |||||
言語 | en | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | ファイル公開:2019/05/01 | |||||
言語 | ja | |||||
出版者 | ||||||
出版者 | Springer | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1007/s00234-018-2002-8 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0028-3940 | |||||
書誌情報 |
en : Neuroradiology 巻 60, 号 5, p. 545-555, 発行日 2018-05 |
|||||
著者版フラグ | ||||||
値 | author |