WEKO3
AND
アイテム
{"_buckets": {"deposit": "0cc7a282-3085-44fd-8464-6760cc7e867a"}, "_deposit": {"id": "28668", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "28668"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00028668"}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageStart": "10E726", "bibliographicVolumeNumber": "79", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_10_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "In this study, we investigate designs for polychromators of the ITER edge Thomson scattering system by means of numerical calculations. For this purpose, we discuss the optimum transmission wavelength ranges of the optical filters and the optimum number of filters. Five different filter arrangements, including those with an optical notch filter to eliminate D\u03b1 emission, are compared with each other. The measurement accuracy when using a polychromator is evaluated for midplane port configuration. It is found that the optimum filter number keeping in mind the cost performance cost is 5 or 6. Moreover, the use of an optical notch filter increases the measurement accuracy by approximately 5%.", "subitem_description_type": "Abstract"}]}, "item_10_publisher_32": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.2969285", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "Copyright 2008 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing.The following article appeared in (Review of Scientific Instruments. v.79, n.10, 2008, p.10E726) and may be found at (http://dx.doi.org/10.1063/1.2969285)."}]}, "item_10_select_15": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_61": {"attribute_name": "ISSN\uff08print\uff09", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kajita, Shin"}], "nameIdentifiers": [{"nameIdentifier": "94103", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatae, Takaki"}], "nameIdentifiers": [{"nameIdentifier": "94104", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kusama, Yoshinori"}], "nameIdentifiers": [{"nameIdentifier": "94105", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-11-07"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "1_2969285.pdf", "filesize": [{"value": "491.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 491900.0, "url": {"label": "1_2969285", "url": "https://nagoya.repo.nii.ac.jp/record/28668/files/1_2969285.pdf"}, "version_id": "5b0f5834-c8ac-485b-9ac8-c90857dd6459"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Design study of polychromators for ITER edge Thomson scattering diagnostics", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "Design study of polychromators for ITER edge Thomson scattering diagnostics"}]}, "item_type_id": "10", "owner": "1", "path": ["673/674/675"], "permalink_uri": "http://hdl.handle.net/2237/00030857", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2019-11-07"}, "publish_date": "2019-11-07", "publish_status": "0", "recid": "28668", "relation": {}, "relation_version_is_last": true, "title": ["Design study of polychromators for ITER edge Thomson scattering diagnostics"], "weko_shared_id": null}
Design study of polychromators for ITER edge Thomson scattering diagnostics
http://hdl.handle.net/2237/00030857
0cf38967-5202-441f-8960-922a548f5334
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-07 | |||||
タイトル | ||||||
タイトル | Design study of polychromators for ITER edge Thomson scattering diagnostics | |||||
著者 |
Kajita, Shin
× Kajita, Shin× Hatae, Takaki× Kusama, Yoshinori |
|||||
権利 | ||||||
権利情報 | Copyright 2008 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing.The following article appeared in (Review of Scientific Instruments. v.79, n.10, 2008, p.10E726) and may be found at (http://dx.doi.org/10.1063/1.2969285). | |||||
抄録 | ||||||
内容記述 | In this study, we investigate designs for polychromators of the ITER edge Thomson scattering system by means of numerical calculations. For this purpose, we discuss the optimum transmission wavelength ranges of the optical filters and the optimum number of filters. Five different filter arrangements, including those with an optical notch filter to eliminate Dα emission, are compared with each other. The measurement accuracy when using a polychromator is evaluated for midplane port configuration. It is found that the optimum filter number keeping in mind the cost performance cost is 5 or 6. Moreover, the use of an optical notch filter increases the measurement accuracy by approximately 5%. | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
DOI | ||||||
関連識別子 | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1063/1.2969285 | |||||
ISSN(print) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-6748 | |||||
書誌情報 |
Review of Scientific Instruments 巻 79, 号 10, p. 10E726, 発行日 2008-10 |
|||||
著者版フラグ | ||||||
値 | publisher |