WEKO3
アイテム
Pathological changes of the myocardium in reworsening of anthracycline-induced cardiomyopathy after explant of a left ventricular assist device
https://doi.org/10.18999/nagjms.82.1.129
https://doi.org/10.18999/nagjms.82.1.1296261ade7-bec1-454d-8b26-a1e196e2ee88
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-02-26 | |||||
タイトル | ||||||
タイトル | Pathological changes of the myocardium in reworsening of anthracycline-induced cardiomyopathy after explant of a left ventricular assist device | |||||
言語 | en | |||||
著者 |
Hiraiwa, Hiroaki
× Hiraiwa, Hiroaki× Okumura, Takahiro× Shimizu, Shinya× Arao, Yoshihito× Oishi, Hideo× Kato, Hiroo× Kuwayama, Tasuku× Yamaguchi, Shogo× Haga, Tomoaki× Yokoi, Tsuyoshi× Kondo, Toru× Sugiura, Yuki× Kano, Naoaki× Watanabe, Naoki× Fukaya, Kenji× Furusawa, Kenji× Sawamura, Akinori× Morimoto, Ryota× Fujimoto, Kazuro× Mutsuga, Masato× Usui, Akihiko× Murohara, Toyoaki |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報Resource | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||
権利情報 | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | anthracycline-induced cardiomyopathy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | left ventricular assist device | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cardiac pathology | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | reworsening heart failure | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We herein report the long-term changes in cardiac function and pathological findings after successful explantation of a left ventricular assist device in a 42-year-old patient with anthracycline-induced cardiomyopathy with reworsening heart failure. Endomyocardial biopsy samples revealed that the cardiomyocyte diameter decreased and collagen volume fraction increased just after left ventricular assist device explantation. The collagen volume fraction decreased after 6 months, despite preserved systolic function. At 5 years after left ventricular assist device explantation, the systolic function markedly decreased and cardiomyocyte diameter increased. Pathological changes of the myocardium may enable the identification of cardiac dysfunction prior to echocardiographic changes in patients with reworsening heart failure after left ventricular assist device explantation. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.82.1.129 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/821.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 82, 号 1, p. 129-134, 発行日 2020-02 |
|||||
著者版フラグ | ||||||
値 | publisher |