ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "dd80e669-7c48-495e-9e27-dd94cc1617f5"}, "_deposit": {"id": "30866", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "30866"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00030866", "sets": ["2585"]}, "author_link": ["102193"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1982-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "128", "bibliographicPageStart": "91", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "Memoirs of the Faculty of Engineering, Nagoya University", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "It is considered desirable that air-conditioning for large spaces should be restricted only to the space within the occupied zone from the viewpoint of economical feasibility and energy conservation. This is a report on the application of the occupied zone air-conditioning to three different large spaces : an exposition hall, a sport hall and a factory of large machine assembly at constant temperature. The distribution of air and temperature were first examined by the experiments with the scaled models followed by the actual measurements. The results obtained by the experiments have proved that the proposed similarity theory on space air distribution can be verified after comparing them with the predicted values. The heat load calculation method for the occupied zone air-conditioning is also proposed in this paper. In addition, the performance of the induction type of outlets suitable for large spaces are analyzed by experiments in detail.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/memfenu.33.2.91", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Faculty of Engineering, Nagoya University", "subitem_publisher_language": "en"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7657", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakahara, Nobuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "102193", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-11-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "33-2-01.pdf", "filesize": [{"value": "4.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 4600000.0, "url": {"label": "33-2-01.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/30866/files/33-2-01.pdf"}, "version_id": "47b81e82-08c8-46b9-981b-5450fddff4c4"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "1", "path": ["2585"], "permalink_uri": "https://doi.org/10.18999/memfenu.33.2.91", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2020-11-24"}, "publish_date": "2020-11-24", "publish_status": "0", "recid": "30866", "relation": {}, "relation_version_is_last": true, "title": ["Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements"], "weko_shared_id": -1}
  1. B200 工学部/工学研究科
  2. B200b 紀要
  3. Memoirs of the Faculty of Engineering, Nagoya University
  4. 33(2)

Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements

https://doi.org/10.18999/memfenu.33.2.91
https://doi.org/10.18999/memfenu.33.2.91
dd5ab28d-d7d3-4ea9-b93b-6d80d61b3499
名前 / ファイル ライセンス アクション
33-2-01.pdf 33-2-01.pdf (4.6 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2020-11-24
タイトル
タイトル Verification of similarity theory on space air distribution and study on occupied zone air-conditioning for large spaces through scaled model experiments and actual measurements
言語 en
著者 Nakahara, Nobuo

× Nakahara, Nobuo

WEKO 102193

en Nakahara, Nobuo

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
抄録
内容記述 It is considered desirable that air-conditioning for large spaces should be restricted only to the space within the occupied zone from the viewpoint of economical feasibility and energy conservation. This is a report on the application of the occupied zone air-conditioning to three different large spaces : an exposition hall, a sport hall and a factory of large machine assembly at constant temperature. The distribution of air and temperature were first examined by the experiments with the scaled models followed by the actual measurements. The results obtained by the experiments have proved that the proposed similarity theory on space air distribution can be verified after comparing them with the predicted values. The heat load calculation method for the occupied zone air-conditioning is also proposed in this paper. In addition, the performance of the induction type of outlets suitable for large spaces are analyzed by experiments in detail.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 Faculty of Engineering, Nagoya University
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/memfenu.33.2.91
ID登録タイプ JaLC
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0027-7657
書誌情報 en : Memoirs of the Faculty of Engineering, Nagoya University

巻 33, 号 2, p. 91-128, 発行日 1982-03-31
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 08:40:48.779007
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3