WEKO3
アイテム
{"_buckets": {"deposit": "116294ea-1d86-4923-9f12-d087ae839414"}, "_deposit": {"id": "31259", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "31259"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00031259", "sets": ["2623"]}, "author_link": ["103185"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1967-03-30", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "201", "bibliographicPageStart": "182", "bibliographicVolumeNumber": "18", "bibliographic_titles": [{"bibliographic_title": "Memoirs of the Faculty of Engineering, Nagoya University", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The mathematical studies of optimal control processes are based on many idealized assumptions. When disturbances that are not known even statisically are considered, the optimum-controller must be readjusted every time the disturbances occur and the parameters of the plant must be compensated so as to maintain the deviation from the expected optimal state within some allowable limit. The control scheme can be realized only by using a high speed digital computer on its feebdack path. This study presents all the mathematical conditions that are necessary to the scheme and accessible to modern high speed computers. The magnitude of disturbances (plant parameter variation) is estimated by solving an equation of observation that relates the parameter disturbances to the plant dynamic sensitivity coefficients. The deviation of the performance index (PI) is also calculated by means of the coefficients of PI variation. To a given margin for the deviation of PI, one simple procedure by which the deviation can be reduced to a value within the margin is proposed as an example.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/memfenu.18.2.182", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Faculty of Engineering, Nagoya University", "subitem_publisher_language": "en"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7657", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sugiura, Ichiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "103185", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-02-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "18-2-05.pdf", "filesize": [{"value": "1.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 1900000.0, "url": {"label": "18-2-05.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/31259/files/18-2-05.pdf"}, "version_id": "86975ccb-ca82-4251-ae9e-9431232eb8e0"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Adaptive Optimalizing control utilizing open loop type optimum-controller and the sensitivity coefficients", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Adaptive Optimalizing control utilizing open loop type optimum-controller and the sensitivity coefficients", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "1", "path": ["2623"], "permalink_uri": "https://doi.org/10.18999/memfenu.18.2.182", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2021-02-04"}, "publish_date": "2021-02-04", "publish_status": "0", "recid": "31259", "relation": {}, "relation_version_is_last": true, "title": ["Adaptive Optimalizing control utilizing open loop type optimum-controller and the sensitivity coefficients"], "weko_shared_id": -1}
Adaptive Optimalizing control utilizing open loop type optimum-controller and the sensitivity coefficients
https://doi.org/10.18999/memfenu.18.2.182
https://doi.org/10.18999/memfenu.18.2.182d0eabd8d-11d5-4d51-98f3-41b7108bc221
名前 / ファイル | ライセンス | アクション |
---|---|---|
18-2-05.pdf (1.9 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-02-04 | |||||
タイトル | ||||||
タイトル | Adaptive Optimalizing control utilizing open loop type optimum-controller and the sensitivity coefficients | |||||
言語 | en | |||||
著者 |
Sugiura, Ichiro
× Sugiura, Ichiro |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
抄録 | ||||||
内容記述 | The mathematical studies of optimal control processes are based on many idealized assumptions. When disturbances that are not known even statisically are considered, the optimum-controller must be readjusted every time the disturbances occur and the parameters of the plant must be compensated so as to maintain the deviation from the expected optimal state within some allowable limit. The control scheme can be realized only by using a high speed digital computer on its feebdack path. This study presents all the mathematical conditions that are necessary to the scheme and accessible to modern high speed computers. The magnitude of disturbances (plant parameter variation) is estimated by solving an equation of observation that relates the parameter disturbances to the plant dynamic sensitivity coefficients. The deviation of the performance index (PI) is also calculated by means of the coefficients of PI variation. To a given margin for the deviation of PI, one simple procedure by which the deviation can be reduced to a value within the margin is proposed as an example. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | Faculty of Engineering, Nagoya University | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/memfenu.18.2.182 | |||||
ID登録タイプ | JaLC | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7657 | |||||
書誌情報 |
en : Memoirs of the Faculty of Engineering, Nagoya University 巻 18, 号 2, p. 182-201, 発行日 1967-03-30 |
|||||
著者版フラグ | ||||||
値 | publisher |