ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "e30c93b3-7016-4434-8267-e1a9bfe2b546"}, "_deposit": {"id": "31327", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "31327"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00031327", "sets": ["501"]}, "author_link": ["103401", "103402"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "1401", "bibliographicPageStart": "1396", "bibliographicVolumeNumber": "30", "bibliographic_titles": [{"bibliographic_title": "Pediatric Anesthesia", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background: Oscillometric noninvasive blood pressure and/or invasive intra‐arterial blood pressure are commonly used to measure the systolic, diastolic, and mean components of blood pressure. Agreement between the two methods has been reported in adults, children, and infants, but rarely in neonates, especially under general anesthesia. Aims: This retrospective study compared the agreement of each measured blood pressure value (oscillometric noninvasive or invasive intra‐arterial blood pressure monitoring) in term neonates under general anesthesia. Methods: Data were collected from neonates born at ≥36 weeks of gestation whose body weight was ≥2500 g and who underwent abdominal or noncardiac thoracic surgery with both oscillometric noninvasive and invasive intra‐arterial blood pressure measurements from January 2015 to March 2020. The primary outcome was the agreement of systolic, diastolic, and mean blood pressure values between the two methods using Bland‐Altman analysis. Results: Paired blood pressure measurements (n = 1193) from 67 cases were compared. In Bland‐Altman analysis, bias (standard deviation), 95% limits of agreement, and percentage error were −9.3 (8.4), −26.1‐7.6, and 26.9% for systolic; 1.6 (6.5), −11.3‐14.6, and 38.7% for diastolic; and −1.3 (5.8), −13.0‐10.3, and 26.9% for mean blood pressure, respectively. During low blood pressure (intra‐arterial mean blood pressure ≤30 mm Hg), the biases (standard deviation) of systolic, diastolic, and mean blood pressure were −11.4 (5.7), −0.7 (3.7), and −5.1 (4.2), whereas during high blood pressure (intra‐arterial mean blood pressure ≥60 mm Hg), the values were 0.1 (9.7), 5.6 (9.4), and 6.4 (7.4), respectively. Conclusions: Based on the bias and percentage error, the mean blood pressure exhibited the most acceptable agreement between oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia. However, during hypertension or hypotension, there was a large discrepancy between the two methods.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "ファイル公開:2021-12-01", "subitem_description_language": "ja", "subitem_description_type": "Other"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1111/pan.14020", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "This is the peer reviewed version of the following article: [ Fujii, T, Nishiwaki, K. Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study. Pediatr. Anesth. 2020; 30: 1396– 1401. https://doi.org/10.1111/pan.14020]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_10_source_id_61": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "1155-5645", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Fujii, Tasuku", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "103401", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishiwaki, Kimitoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "103402", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-12-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Manuscript_Paediatr_Anaesth_2020_nagoya-u.pdf", "filesize": [{"value": "939.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 939800.0, "url": {"label": "Manuscript_Paediatr_Anaesth_2020_nagoya-u", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/31327/files/Manuscript_Paediatr_Anaesth_2020_nagoya-u.pdf"}, "version_id": "367efecc-f6cb-4f84-80ed-9718cb6ad65b"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/00033507", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2021-02-09"}, "publish_date": "2021-02-09", "publish_status": "0", "recid": "31327", "relation": {}, "relation_version_is_last": true, "title": ["Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100a 雑誌掲載論文
  3. 学術雑誌

Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study

http://hdl.handle.net/2237/00033507
http://hdl.handle.net/2237/00033507
b04e24e8-9209-4749-9902-3f969c0c186f
名前 / ファイル ライセンス アクション
Manuscript_Paediatr_Anaesth_2020_nagoya-u.pdf Manuscript_Paediatr_Anaesth_2020_nagoya-u (939.8 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-09
タイトル
タイトル Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study
言語 en
著者 Fujii, Tasuku

× Fujii, Tasuku

WEKO 103401

en Fujii, Tasuku

Search repository
Nishiwaki, Kimitoshi

× Nishiwaki, Kimitoshi

WEKO 103402

en Nishiwaki, Kimitoshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 This is the peer reviewed version of the following article: [ Fujii, T, Nishiwaki, K. Comparing oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study. Pediatr. Anesth. 2020; 30: 1396– 1401. https://doi.org/10.1111/pan.14020]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.
抄録
内容記述 Background: Oscillometric noninvasive blood pressure and/or invasive intra‐arterial blood pressure are commonly used to measure the systolic, diastolic, and mean components of blood pressure. Agreement between the two methods has been reported in adults, children, and infants, but rarely in neonates, especially under general anesthesia. Aims: This retrospective study compared the agreement of each measured blood pressure value (oscillometric noninvasive or invasive intra‐arterial blood pressure monitoring) in term neonates under general anesthesia. Methods: Data were collected from neonates born at ≥36 weeks of gestation whose body weight was ≥2500 g and who underwent abdominal or noncardiac thoracic surgery with both oscillometric noninvasive and invasive intra‐arterial blood pressure measurements from January 2015 to March 2020. The primary outcome was the agreement of systolic, diastolic, and mean blood pressure values between the two methods using Bland‐Altman analysis. Results: Paired blood pressure measurements (n = 1193) from 67 cases were compared. In Bland‐Altman analysis, bias (standard deviation), 95% limits of agreement, and percentage error were −9.3 (8.4), −26.1‐7.6, and 26.9% for systolic; 1.6 (6.5), −11.3‐14.6, and 38.7% for diastolic; and −1.3 (5.8), −13.0‐10.3, and 26.9% for mean blood pressure, respectively. During low blood pressure (intra‐arterial mean blood pressure ≤30 mm Hg), the biases (standard deviation) of systolic, diastolic, and mean blood pressure were −11.4 (5.7), −0.7 (3.7), and −5.1 (4.2), whereas during high blood pressure (intra‐arterial mean blood pressure ≥60 mm Hg), the values were 0.1 (9.7), 5.6 (9.4), and 6.4 (7.4), respectively. Conclusions: Based on the bias and percentage error, the mean blood pressure exhibited the most acceptable agreement between oscillometric noninvasive and invasive intra‐arterial blood pressure monitoring in term neonates under general anesthesia. However, during hypertension or hypotension, there was a large discrepancy between the two methods.
言語 en
内容記述タイプ Abstract
内容記述
内容記述 ファイル公開:2021-12-01
言語 ja
内容記述タイプ Other
出版者
言語 en
出版者 Wiley
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1111/pan.14020
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 1155-5645
書誌情報 en : Pediatric Anesthesia

巻 30, 号 12, p. 1396-1401, 発行日 2020-12
著者版フラグ
値 author
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 08:27:53.584550
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3