WEKO3
アイテム
Insulation performance of pressurized liquid helium under quench-induced thermal bubble disturbance for superconducting power apparatus
http://hdl.handle.net/2237/6753
http://hdl.handle.net/2237/6753b9cabfe2-2484-4654-87ab-3caf50a9885d
名前 / ファイル | ライセンス | アクション |
---|---|---|
00775627.pdf (1.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-07-28 | |||||
タイトル | ||||||
タイトル | Insulation performance of pressurized liquid helium under quench-induced thermal bubble disturbance for superconducting power apparatus | |||||
言語 | en | |||||
著者 |
Chigusa, S.
× Chigusa, S.× Maeda, H.× Taniguchi, Y.× Hayakawa, N.× Okubo, H. |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | Copyright © 1999 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have been studying quench-induced 'dynamic' breakdown characteristics of LHe * and have already found that the electrical insulation performance of LHe was degraded drastically by the thermal bubble disturbance due to quench of superconductors. In this paper, in order to improve the insulation performance of LHe under quench conditions, we measured dynamic breakdown and prebreakdown characteristics of pressurized LHe. Experimental results revealed that breakdown voltage of LHe under quench conditions at 0.2 MPa was greatly improved, reaching 2 to 4x compared with that at atmospheric pressure under both uniform and non-uniform electric fields. Moreover, for practical and efficient insulation design of superconducting power apparatus, we investigated the dynamic breakdown voltage of LHe as functions of' pressure and gap length. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | IEEE | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/94.775627 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1070-9878 | |||||
書誌情報 |
en : IEEE Transactions on Dielectrics and Electrical Insulation [see also IEEE Transactions on Electrical Insulation] 巻 6, 号 3, p. 385-392, 発行日 1999-06 |
|||||
フォーマット | ||||||
値 | application/pdf | |||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/6753 | |||||
識別子タイプ | HDL |