{"_buckets": {"deposit": "d182191c-7bfa-40cf-92d9-21305f7f19f0"}, "_deposit": {"id": "5220", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "5220"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00005220", "sets": ["322"]}, "author_link": ["13177", "13178", "13179", "13180", "13181", "13182", "13183", "13184"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1997-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "1036", "bibliographicPageStart": "1033", "bibliographicVolumeNumber": "7", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on applied Superconductivity", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed a “Prospective Power Transmission Model System Integrated under Superconducting Environment”, abbreviated to PROMISE, with the transmission capability of 6kV-1000kVA. The PROMISE consists of a superconducting transformer (SC-Tr), a superconducting fault current limiter (SC-FCL) and a superconducting power cable (SC-power cable). These components are cooled down at liquid helium (LHe) temperature, 4.2K, in a cryostat with a volume of 854l. The paper indicates a computing procedure of a total heat leak P\u003csub\u003eleak\u003c/sub\u003e into the cryostat with a volume of 854l. The paper indicates a computing procedure of a total heat leak P\u003csub\u003eleak\u003c/sub\u003e into the cryostat and discusses transmission losses of the superconducting electronic power system, which evaporate the LHe. P\u003csub\u003eleak\u003c/sub\u003e, core loss P\u003csub\u003ecore\u003c/sub\u003e of the SC-Tr and a.c. loss P\u003csub\u003eac\u003c/sub\u003e in the supercondubtor were measured in the PROMISE to be 43W, 180W, and 50W, respectively. The measured P\u003csub\u003eleak\u003c/sub\u003e agreed with the theoretical one. In the superconducting power transmission system, the power to operate the refrigerator for liquqefying the evaporated helium must be taken as the transmission loss. If the penalty factor was 500, the transmission loss was estimated to be 137kW and took 13.7% of the transmission capability in the PROMISE.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/6804"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/77.614694", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 1997 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1051-8223", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Shimizu, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13177", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yokomizu, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13178", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kato, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13179", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tang, Y. J.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13180", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumura, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13181", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kito, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13182", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satoh, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13183", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satoh, W.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13184", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ap_su_7_2_1033.pdf", "filesize": [{"value": "3.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 3200000.0, "url": {"label": "ap_su_7_2_1033.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/5220/files/ap_su_7_2_1033.pdf"}, "version_id": "516116e6-b2c0-4d82-9bdb-691f3ca6e3ad"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Transmission loss of prospective power transmission model system integrated under superconducting environment", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Transmission loss of prospective power transmission model system integrated under superconducting environment", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/6804", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2006-08-07"}, "publish_date": "2006-08-07", "publish_status": "0", "recid": "5220", "relation": {}, "relation_version_is_last": true, "title": ["Transmission loss of prospective power transmission model system integrated under superconducting environment"], "weko_shared_id": -1}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

Transmission loss of prospective power transmission model system integrated under superconducting environment

http://hdl.handle.net/2237/6804
http://hdl.handle.net/2237/6804
7771ac46-4b30-4d89-9242-8706df80a3e2
名前 / ファイル ライセンス アクション
ap_su_7_2_1033.pdf ap_su_7_2_1033.pdf (3.2 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-08-07
タイトル
タイトル Transmission loss of prospective power transmission model system integrated under superconducting environment
言語 en
著者 Shimizu, H.

× Shimizu, H.

WEKO 13177

en Shimizu, H.

Search repository
Yokomizu, Y.

× Yokomizu, Y.

WEKO 13178

en Yokomizu, Y.

Search repository
Kato, T.

× Kato, T.

WEKO 13179

en Kato, T.

Search repository
Tang, Y. J.

× Tang, Y. J.

WEKO 13180

en Tang, Y. J.

Search repository
Matsumura, T.

× Matsumura, T.

WEKO 13181

en Matsumura, T.

Search repository
Kito, Y.

× Kito, Y.

WEKO 13182

en Kito, Y.

Search repository
Satoh, K.

× Satoh, K.

WEKO 13183

en Satoh, K.

Search repository
Satoh, W.

× Satoh, W.

WEKO 13184

en Satoh, W.

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 Copyright © 1997 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.
抄録
内容記述 We have developed a “Prospective Power Transmission Model System Integrated under Superconducting Environment”, abbreviated to PROMISE, with the transmission capability of 6kV-1000kVA. The PROMISE consists of a superconducting transformer (SC-Tr), a superconducting fault current limiter (SC-FCL) and a superconducting power cable (SC-power cable). These components are cooled down at liquid helium (LHe) temperature, 4.2K, in a cryostat with a volume of 854l. The paper indicates a computing procedure of a total heat leak P<sub>leak</sub> into the cryostat with a volume of 854l. The paper indicates a computing procedure of a total heat leak P<sub>leak</sub> into the cryostat and discusses transmission losses of the superconducting electronic power system, which evaporate the LHe. P<sub>leak</sub>, core loss P<sub>core</sub> of the SC-Tr and a.c. loss P<sub>ac</sub> in the supercondubtor were measured in the PROMISE to be 43W, 180W, and 50W, respectively. The measured P<sub>leak</sub> agreed with the theoretical one. In the superconducting power transmission system, the power to operate the refrigerator for liquqefying the evaporated helium must be taken as the transmission loss. If the penalty factor was 500, the transmission loss was estimated to be 137kW and took 13.7% of the transmission capability in the PROMISE.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 IEEE
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/77.614694
ISSN
収録物識別子タイプ PISSN
収録物識別子 1051-8223
書誌情報 en : IEEE Transactions on applied Superconductivity

巻 7, 号 2, p. 1033-1036, 発行日 1997-06
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/6804
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:15:42.098611
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3