{"_buckets": {"deposit": "e26ae2c2-a9d8-4e4e-8b5e-49013e49e381"}, "_deposit": {"id": "5289", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "5289"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00005289", "sets": ["322"]}, "author_link": ["13402", "13403", "13404", "13405", "13406"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1997-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "134", "bibliographicPageStart": "127", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Dielectrics and Electrical Insulation [see also IEEE Transactions on Electrical Insulation]", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We investigated the area and volume effects on the breakdown strength in liquid nitrogen (LN_2) to discuss breakdown mechanism in cryogenic liquids for superconducting power apparatus. We measured breakdown voltages in LN_2 with and without thermal bubbles over a very wide range of the electrode size. Experimental results revealed that breakdown mechanism changed from area dominant to volume effective region at the larger electrode configurations LN_2. Moreover, we discussed the contribution rate of area and volume effects appeared in breakdown characteristics in LN_2 under thermal bubble condition, as a phenomenon peculiar to cryogenic liquids. Consequently, we pointed out that it is very important to consider both thermal bubbles and electrode surface condition for HV insulation of superconducting power appartus.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/6876"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/94.590883", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 1997 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayakawa, N.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13402", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakakibara, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13403", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Goshima, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13404", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hikita, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13405", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okubo, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13406", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "di_el_ins_4_1_127.pdf", "filesize": [{"value": "3.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 3400000.0, "url": {"label": "di_el_ins_4_1_127.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/5289/files/di_el_ins_4_1_127.pdf"}, "version_id": "1aeabedb-fc93-46df-a459-201c185bfc55"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Breakdown mechanism of liquid nitrogen viewed from area and volume effects", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Breakdown mechanism of liquid nitrogen viewed from area and volume effects", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/6876", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2006-08-31"}, "publish_date": "2006-08-31", "publish_status": "0", "recid": "5289", "relation": {}, "relation_version_is_last": true, "title": ["Breakdown mechanism of liquid nitrogen viewed from area and volume effects"], "weko_shared_id": -1}
Breakdown mechanism of liquid nitrogen viewed from area and volume effects
http://hdl.handle.net/2237/6876
http://hdl.handle.net/2237/6876a9fb26da-24c7-400b-be91-90ccb8686dc5
名前 / ファイル | ライセンス | アクション |
---|---|---|
di_el_ins_4_1_127.pdf (3.4 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-08-31 | |||||
タイトル | ||||||
タイトル | Breakdown mechanism of liquid nitrogen viewed from area and volume effects | |||||
言語 | en | |||||
著者 |
Hayakawa, N.
× Hayakawa, N.× Sakakibara, H.× Goshima, H.× Hikita, M.× Okubo, H. |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | Copyright © 1997 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org. | |||||
抄録 | ||||||
内容記述 | We investigated the area and volume effects on the breakdown strength in liquid nitrogen (LN_2) to discuss breakdown mechanism in cryogenic liquids for superconducting power apparatus. We measured breakdown voltages in LN_2 with and without thermal bubbles over a very wide range of the electrode size. Experimental results revealed that breakdown mechanism changed from area dominant to volume effective region at the larger electrode configurations LN_2. Moreover, we discussed the contribution rate of area and volume effects appeared in breakdown characteristics in LN_2 under thermal bubble condition, as a phenomenon peculiar to cryogenic liquids. Consequently, we pointed out that it is very important to consider both thermal bubbles and electrode surface condition for HV insulation of superconducting power appartus. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | IEEE | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/94.590883 | |||||
書誌情報 |
en : IEEE Transactions on Dielectrics and Electrical Insulation [see also IEEE Transactions on Electrical Insulation] 巻 4, 号 1, p. 127-134, 発行日 1997-02 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/6876 | |||||