WEKO3
アイテム
Effectiveness of Centrifuge-induced Artificial Gravity with Ergometric Exercise as a Countermeasure during Simulated Microgravity Exposure in Humans
https://doi.org/10.18999/envm.47.76
https://doi.org/10.18999/envm.47.7645972ae7-72bd-4947-a724-20b8997d596f
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-04-09 | |||||
タイトル | ||||||
タイトル | Effectiveness of Centrifuge-induced Artificial Gravity with Ergometric Exercise as a Countermeasure during Simulated Microgravity Exposure in Humans | |||||
言語 | en | |||||
著者 |
Iwase, Satoshi
× Iwase, Satoshi× Fu, Qi× Morimoto, Eiichi× Takada, Hiroki× Kamiya, Atsunori× Michikami, Daisaku× Kawanokuchi, Jun× Shiozawa, Tomoki× Hirayanagi, Kaname× Iwasaki, Ken-ichi× Yajima, Kazuyoshi× Mano, Tadaaki |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Artificial gravity | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ergometric exercise | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | deconditioning | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | microneurography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | sympathetic nerve activity | |||||
抄録 | ||||||
内容記述 | To test the effectiveness of centrifuge-induced artificial gravity with ergometric exercise, 12 healthy young men (20.7±1.9yrs) were exposed to simulated microgravity for 14 days of-6°head-down bedrest. Half the subjects were randomly selected and loaded 1.2 G artificial gravity with 60 W (four out of six subjects) or 40 W (two out of six subjects) of ergometric workload on days 1,2,3,5,7,9,11.12,13,14(CM group). The rest of the subjects served as the control. Anti-G score, defined as the G-load x running time to the endpoint, was significantly elongated by the load of the centrifuge-ergometer.Plasma volume loss was suppressed(-5.0±2.4 vs-16.4±1.9%),and fluid volume shift was prevented by the countermeasure load. Elevated heart rate and muscle sympathetic nerve activity after bedrest were counteracted, and exaggerated response to head-up tilt was also suppressed. Centrifuge-induced artificial gravity with exercise is effective in preventing cardiovascular deconditioning due to microgravity exposure, however, as effective and appropriate regimen (magnitude of G-load and exercise workload)should be determined in future studies. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
内容記述 | ||||||
内容記述 | 国立情報学研究所で電子化したコンテンツを使用している。 | |||||
言語 | ja | |||||
内容記述タイプ | Other | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | Research Institute of Environmental Medicine, Nagoya University | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/envm.47.76 | |||||
ID登録タイプ | JaLC | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0287-0517 | |||||
書誌情報 |
en : Environmental Medicine : annual report of the Research Institute of Environmental Medicine, Nagoya University 巻 47, p. 76-80, 発行日 2003-12 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/7604 | |||||
識別子タイプ | HDL |