{"_buckets": {"deposit": "6fc08d5f-fe1f-4b5f-810f-3ad21e3bd10c"}, "_deposit": {"id": "7118", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7118"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00007118", "sets": ["322"]}, "author_link": ["19240", "19241", "19242", "19243", "19244", "19245"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "10E704", "bibliographicPageStart": "10E704", "bibliographicVolumeNumber": "77", "bibliographic_titles": [{"bibliographic_title": "REVIEW OF SCIENTIFIC INSTRUMENTS", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "For ion temperature measurement in the ITER high power operation phase, we propose a promising high-energy-resolution neutron spectrometer based on the associated particle detection using a proton recoil telescope and a time-of-flight spectrometer. To verify the operational principle and the basic performance of this system, we have set up a prototype system through Monte Carlo simulations and carried out a preliminary experiment with a deuterium-tritium (DT) neutron beam at the Fusion Neutronics Source, JAEA. The results have demonstrated that the energy resolution could be achieved around 3.3% (in full width at half maximum) for DT neutrons. In addition, the design consideration of this system for an application to ITER is given on the detection efficiency, the applicable range in the ITER operation, and the detector lifetime.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/8796"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "American Institute of Physics", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.2221691", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (2006) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Naoi, N.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19240", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Asai, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19241", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iguchi, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19242", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19243", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawarabayashi, J.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19244", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishitani, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19245", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "RevSciInst_77-10E704.pdf", "filesize": [{"value": "116.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 116100.0, "url": {"label": "RevSciInst_77-10E704.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/7118/files/RevSciInst_77-10E704.pdf"}, "version_id": "a5610cb0-0de6-4571-b3c8-d92add47026e"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/8796", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-09-28"}, "publish_date": "2007-09-28", "publish_status": "0", "recid": "7118", "relation": {}, "relation_version_is_last": true, "title": ["Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER"], "weko_shared_id": -1}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER

http://hdl.handle.net/2237/8796
http://hdl.handle.net/2237/8796
6c060cba-43ca-48ac-a150-2157fcde9351
名前 / ファイル ライセンス アクション
RevSciInst_77-10E704.pdf RevSciInst_77-10E704.pdf (116.1 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-09-28
タイトル
タイトル Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER
言語 en
著者 Naoi, N.

× Naoi, N.

WEKO 19240

en Naoi, N.

Search repository
Asai, K.

× Asai, K.

WEKO 19241

en Asai, K.

Search repository
Iguchi, T.

× Iguchi, T.

WEKO 19242

en Iguchi, T.

Search repository
Watanabe, K.

× Watanabe, K.

WEKO 19243

en Watanabe, K.

Search repository
Kawarabayashi, J.

× Kawarabayashi, J.

WEKO 19244

en Kawarabayashi, J.

Search repository
Nishitani, T.

× Nishitani, T.

WEKO 19245

en Nishitani, T.

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 Copyright (2006) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.
抄録
内容記述 For ion temperature measurement in the ITER high power operation phase, we propose a promising high-energy-resolution neutron spectrometer based on the associated particle detection using a proton recoil telescope and a time-of-flight spectrometer. To verify the operational principle and the basic performance of this system, we have set up a prototype system through Monte Carlo simulations and carried out a preliminary experiment with a deuterium-tritium (DT) neutron beam at the Fusion Neutronics Source, JAEA. The results have demonstrated that the energy resolution could be achieved around 3.3% (in full width at half maximum) for DT neutrons. In addition, the design consideration of this system for an application to ITER is given on the detection efficiency, the applicable range in the ITER operation, and the detector lifetime.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 American Institute of Physics
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1063/1.2221691
ISSN
収録物識別子タイプ PISSN
収録物識別子 0034-6748
書誌情報 en : REVIEW OF SCIENTIFIC INSTRUMENTS

巻 77, 号 10, p. 10E704-10E704, 発行日 2006-10
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/8796
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 12:24:58.097005
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3