WEKO3
アイテム
Micromachined sample divider for analyzing biochemical reaction based on single molecules
http://hdl.handle.net/2237/11138
http://hdl.handle.net/2237/11138adde6b3e-cea4-46d3-b6e7-92e811596228
名前 / ファイル | ライセンス | アクション |
---|---|---|
08_MEMS_Koyama.pdf (1.1 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-02-23 | |||||
タイトル | ||||||
タイトル | Micromachined sample divider for analyzing biochemical reaction based on single molecules | |||||
言語 | en | |||||
著者 |
Koyama, M.
× Koyama, M.× Imai, R.× Shikida, M.× Okochi, M.× Tsuchiya, H.× Honda, H.× Sato, K.× 佐藤, 一雄 |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | Copyright © 2008 IEEE. Reprinted from IEEE 21st International Conference on Micro Electro Mechanical Systems, 2008, MEMS, p.618-621. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We proposed novel type of a sample divider, which can easily divide the sample solution into multiple small amount of it on a chip, for single molecule analysis. We used the composite of a PDMS and an expancel^R as a material, and fabricated the sample divider structure by applying the mold process. We investigated the PDMS and the expancel mixture fraction dependency, and effect of the heating time, on the channel closing performance. The flow channels were successfully closed when the volume ratio between the expancel and PDMS solution was 1:2 and the heating time was 15 minutes. From these results, we concluded that the proposed device is useful as the sample divider, if we optimally designed. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | IEEE | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/MEMSYS.2008.4443732 | |||||
ISBN | ||||||
関連タイプ | isPartOf | |||||
識別子タイプ | ISBN | |||||
関連識別子 | 978-1-4244-1793-3 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1084-6999 | |||||
書誌情報 |
en : IEEE 21st International Conference on Micro Electro Mechanical Systems (MEMS 2008) p. 618-621, 発行日 2008-01 |
|||||
フォーマット | ||||||
値 | application/pdf | |||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/11138 | |||||
識別子タイプ | HDL |