WEKO3
アイテム
{"_buckets": {"deposit": "234b1968-766e-4cc5-9464-39005b517006"}, "_deposit": {"id": "17346", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "17346"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00017346", "sets": ["501"]}, "author_link": ["51020", "51021", "51022", "51023", "51024", "51025", "51026", "51027", "51028", "51029", "51030", "51031", "51032", "51033"], "item_10_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Magnetization Transfer Ratio in Nasopharyngeal Aneuploid Tumor", "subitem_alternative_title_language": "en"}]}, "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1996-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "292", "bibliographicPageStart": "289", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "日本磁気共鳴医学会雑誌", "bibliographic_titleLang": "ja"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Magnetization transfer ratios (MTRs) and DNA index of nasopharyngeal tumor were measured in 5 patients using a conventional 1.5 T MR system. The MTRs were calculated using a pair of images; one image was obtained with a MT-saturating-pulse on, and the other with the saturating-pulse off. The MTRs were defined as a percentage of the signal intensity between the two images. In the present study, the value of MTRs of aneuploid tumor was larger than those of diploid tumors. These results suggested that the MTRs could make a new indicator for maliginity of the tumors.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/19431"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本磁気共鳴医学会", "subitem_publisher_language": "ja"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-9457", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松島, 秀", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51020", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内山, 幸男", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51021", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大崎, 光", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51022", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "不破, 信和", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51023", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安藤, 学", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51024", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田, 尚利", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51025", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "紀ノ定, 保臣", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "51026", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MATSUSHIMA, Shigeru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51027", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "UCHIYAMA, Yukio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51028", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OHSAKI, Hikaru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51029", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "FUWA, Nobukazu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51030", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ANDOH, Manabu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51031", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MAEDA, Hisatoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51032", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KIKOSADA, Yasutomi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "51033", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "50_maeda.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "50_maeda.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/17346/files/50_maeda.pdf"}, "version_id": "2b4f57de-ad98-480a-952d-b6e47f5f4f38"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "magnetization transfer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "DNA aneuploidy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "nasopharyngeal cancer", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "異数倍数体を示す上咽頭腫瘍におけるmagnetization transfer ratio", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "異数倍数体を示す上咽頭腫瘍におけるmagnetization transfer ratio", "subitem_title_language": "ja"}]}, "item_type_id": "10", "owner": "1", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/19431", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2014-02-25"}, "publish_date": "2014-02-25", "publish_status": "0", "recid": "17346", "relation": {}, "relation_version_is_last": true, "title": ["異数倍数体を示す上咽頭腫瘍におけるmagnetization transfer ratio"], "weko_shared_id": -1}
異数倍数体を示す上咽頭腫瘍におけるmagnetization transfer ratio
http://hdl.handle.net/2237/19431
http://hdl.handle.net/2237/1943107772920-b120-4adb-bdce-ee2466169d94
名前 / ファイル | ライセンス | アクション |
---|---|---|
50_maeda.pdf (1.1 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-02-25 | |||||
タイトル | ||||||
タイトル | 異数倍数体を示す上咽頭腫瘍におけるmagnetization transfer ratio | |||||
言語 | ja | |||||
その他のタイトル | ||||||
その他のタイトル | Magnetization Transfer Ratio in Nasopharyngeal Aneuploid Tumor | |||||
言語 | en | |||||
著者 |
松島, 秀
× 松島, 秀× 内山, 幸男× 大崎, 光× 不破, 信和× 安藤, 学× 前田, 尚利× 紀ノ定, 保臣× MATSUSHIMA, Shigeru× UCHIYAMA, Yukio× OHSAKI, Hikaru× FUWA, Nobukazu× ANDOH, Manabu× MAEDA, Hisatoshi× KIKOSADA, Yasutomi |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | magnetization transfer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | DNA aneuploidy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | nasopharyngeal cancer | |||||
抄録 | ||||||
内容記述 | Magnetization transfer ratios (MTRs) and DNA index of nasopharyngeal tumor were measured in 5 patients using a conventional 1.5 T MR system. The MTRs were calculated using a pair of images; one image was obtained with a MT-saturating-pulse on, and the other with the saturating-pulse off. The MTRs were defined as a percentage of the signal intensity between the two images. In the present study, the value of MTRs of aneuploid tumor was larger than those of diploid tumors. These results suggested that the MTRs could make a new indicator for maliginity of the tumors. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | ja | |||||
出版者 | 日本磁気共鳴医学会 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0914-9457 | |||||
書誌情報 |
ja : 日本磁気共鳴医学会雑誌 巻 16, 号 6, p. 289-292, 発行日 1996-09 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/19431 | |||||
識別子タイプ | HDL |