Examination of the effectiveness of bedside nasojejunal tube placement using a portable imaging device with a flat panel detector |
|
言語 |
en |
著者 |
Takamoto, Naohiro
Takazawa, Shinya
Yoshida, Yuki
Sasaki, Tamotsu
Nishi, Akira
|
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
権利 |
|
|
言語 |
en |
|
権利情報Resource |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
|
権利情報 |
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
nasojejunal tube |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
portable imaging device |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
fluoroscopy |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
entrance surface dosage |
内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Transporting pediatric patients with severe cardiovascular complications to the fluoroscopy room can be difficult. Therefore, we started using a portable imaging device with a flat panel detector (FPD) for nasojejunal tube (NJT) placement. The purpose of this study was to investigate the differences in length of time of NJT placement and dosage of radiation exposure using a portable imaging device with FPD versus fluoroscopy. Pediatric patients who underwent NJT placement between April 2016 and December 2018 were identified retrospectively from the clinical records. The age, sex, body weight, and height of each child at the time of the procedure as well as the procedure time, outcomes of the procedure, and dosage of radiation exposure was compared between the two groups. In 76 cases of NJT placement (41 patients), there was no significant difference in the success rate of NJT placement between the FPD (90%) and fluoroscopy groups (95%). However, the NJT placement time was significantly longer in the FPD group than in the fluoroscopy group (488 s vs 291 s). According to our calculations, the radiation dosage was lower in the FPD group than in the fluoroscopy group (136 μGy per procedure vs 2819 μGy per procedure). These results suggest that NJT placement using a portable imaging device with an FPD can be an effective method for children who are difficult to transport with an equal success rate and lower dosage of radiation exposure compared with conventional fluoroscopy. |
|
言語 |
en |
出版者 |
|
|
出版者 |
Nagoya University Graduate School of Medicine, School of Medicine |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
ID登録 |
|
|
ID登録 |
10.18999/nagjms.84.4.772 |
|
ID登録タイプ |
JaLC |
関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/844.html |
収録物識別子 |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
0027-7622 |
収録物識別子 |
|
|
収録物識別子タイプ |
EISSN |
|
収録物識別子 |
2186-3326 |
書誌情報 |
en : Nagoya Journal of Medical Science
巻 84,
号 4,
p. 772-781,
発行日 2022-11
|