{"_buckets": {"deposit": "087c9d45-9ccc-4fa5-a757-c28fd2ac35fa"}, "_deposit": {"id": "7841", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7841"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00007841"}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "2388", "bibliographicPageStart": "2385", "bibliographic_titles": [{"bibliographic_title": "Solid-State Sensors, Actuators and Microsystems Conference"}]}]}, "item_10_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "We have previously proposed a magnetic bead handling mechanism for micro-total-analysissystems [1-2] and have developed a palmtop-sized biochemical analysis system [3]. Appropriate agitation is one of the crucial issues in micro-meter-sized fluidic systems. We investigated the agitation produced by using multilayered flat coils and magnetic beads. The beads were magnetically agitated inside the droplet by changing the external magnetic field distribution, and the agitation performance was evaluated by using an enzymatic reaction. The reaction efficiency increased linearly with an increase in the reaction time and was more than four times as efficient with agitation than without agitation.", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/9562"}]}, "item_10_publisher_32": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1109/SENSOR.2007.4300650", "subitem_relation_type_select": "DOI"}}]}, "item_10_relation_8": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "1-4244-0842-3", "subitem_relation_type_select": "ISBN"}}]}, "item_10_rights_12": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "Copyright \u00a9 2007 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University\u2019s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org."}]}, "item_10_select_15": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_text_14": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Koyama, M."}], "nameIdentifiers": [{"nameIdentifier": "22379", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagano, N."}], "nameIdentifiers": [{"nameIdentifier": "22380", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imai, R."}], "nameIdentifiers": [{"nameIdentifier": "22381", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shikida, M."}], "nameIdentifiers": [{"nameIdentifier": "22382", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Honda, H."}], "nameIdentifiers": [{"nameIdentifier": "22383", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okochi, M."}], "nameIdentifiers": [{"nameIdentifier": "22384", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuchiya, H."}], "nameIdentifiers": [{"nameIdentifier": "22385", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, K."}], "nameIdentifiers": [{"nameIdentifier": "22386", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "shik_09.pdf", "filesize": [{"value": "349.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 349900.0, "url": {"label": "shik_09.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/7841/files/shik_09.pdf"}, "version_id": "1134677d-253f-4491-8c76-4c7d17e9012a"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "magnetic beads", "subitem_subject_scheme": "Other"}, {"subitem_subject": "micro-TAS", "subitem_subject_scheme": "Other"}, {"subitem_subject": "agitation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "flat coil", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils"}]}, "item_type_id": "10", "owner": "1", "path": ["320/321/322"], "permalink_uri": "http://hdl.handle.net/2237/9562", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2008-03-04"}, "publish_date": "2008-03-04", "publish_status": "0", "recid": "7841", "relation": {}, "relation_version_is_last": true, "title": ["Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils"], "weko_shared_id": 3}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils

http://hdl.handle.net/2237/9562
c53ad740-8df3-478f-b71f-cd7b2bab12e2
名前 / ファイル ライセンス アクション
shik_09.pdf shik_09.pdf (349.9 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-03-04
タイトル
タイトル Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils
著者 Koyama, M.

× Koyama, M.

WEKO 22379

Koyama, M.

Search repository
Nagano, N.

× Nagano, N.

WEKO 22380

Nagano, N.

Search repository
Imai, R.

× Imai, R.

WEKO 22381

Imai, R.

Search repository
Shikida, M.

× Shikida, M.

WEKO 22382

Shikida, M.

Search repository
Honda, H.

× Honda, H.

WEKO 22383

Honda, H.

Search repository
Okochi, M.

× Okochi, M.

WEKO 22384

Okochi, M.

Search repository
Tsuchiya, H.

× Tsuchiya, H.

WEKO 22385

Tsuchiya, H.

Search repository
Sato, K.

× Sato, K.

WEKO 22386

Sato, K.

Search repository
権利
権利情報 Copyright © 2007 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.
キーワード
主題Scheme Other
主題 magnetic beads
キーワード
主題Scheme Other
主題 micro-TAS
キーワード
主題Scheme Other
主題 agitation
キーワード
主題Scheme Other
主題 flat coil
抄録
内容記述 We have previously proposed a magnetic bead handling mechanism for micro-total-analysissystems [1-2] and have developed a palmtop-sized biochemical analysis system [3]. Appropriate agitation is one of the crucial issues in micro-meter-sized fluidic systems. We investigated the agitation produced by using multilayered flat coils and magnetic beads. The beads were magnetically agitated inside the droplet by changing the external magnetic field distribution, and the agitation performance was evaluated by using an enzymatic reaction. The reaction efficiency increased linearly with an increase in the reaction time and was more than four times as efficient with agitation than without agitation.
内容記述タイプ Abstract
出版者
出版者 IEEE
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
DOI
関連識別子
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1109/SENSOR.2007.4300650
ISBN
関連識別子
識別子タイプ ISBN
関連識別子 1-4244-0842-3
書誌情報 Solid-State Sensors, Actuators and Microsystems Conference

p. 2385-2388, 発行日 2007
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/9562
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 12:15:34.442931
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio